User Tools

Site Tools


direct_access_changes

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
direct_access_changes [2014/01/23 14:03]
twdorris [Installing the file]
direct_access_changes [2016/10/30 06:34]
twdorris [Simple binary files]
Line 20: Line 20:
  
 __General Windows (can be typed into URL line of Explorer or IE browser):__ \\  __General Windows (can be typed into URL line of Explorer or IE browser):__ \\ 
-%USERPROFILE%%%\%%ecmlink%%\%%resources%%\%%records+%USERPROFILE%<​nowiki>​\</​nowiki>​ecmlink<​nowiki>​\</​nowiki>​resources<​nowiki>​\</​nowiki>​records
  
  
Line 27: Line 27:
  
  
-The directory should already exist, so if it doesn'​t,​ you may be looking in the wrong place.+The directory should already exist, so if it doesn'​t,​ you're probably ​looking in the wrong place.
  
  
Line 36: Line 36:
  
 Simply change the one cell in these tables to "​0"​ to disable the corresponding function and hit Save to ECU. Simply change the one cell in these tables to "​0"​ to disable the corresponding function and hit Save to ECU.
 +
 +
 +<font 10px/​arial;;#​000000;;#​ffffff>//​ (You may need to right-click on the file and select "Save link as" to download these files to your computer)</​font>​ // 
  
  
Line 59: Line 62:
 |Engine prime 2g/EVO |{{:​engineprime-2g-e3.properties|engineprime-2g-e3.properties}} ​ |Adjusts the value used to prime the engine once at the start of each cranking attempt. Because the step size is so large, it's best to just select the cell and use the Ctrl+Up/​Down arrows to adjust. A value of zero disables the prime function entirely. A value of 100% is full stock prime value. (2G & EVO1-3 only) | |Engine prime 2g/EVO |{{:​engineprime-2g-e3.properties|engineprime-2g-e3.properties}} ​ |Adjusts the value used to prime the engine once at the start of each cranking attempt. Because the step size is so large, it's best to just select the cell and use the Ctrl+Up/​Down arrows to adjust. A value of zero disables the prime function entirely. A value of 100% is full stock prime value. (2G & EVO1-3 only) |
 |Engine prime 1g |{{:​engineprime-1g.properties|engineprime-1g.properties}} ​ |1G DSM version of the above. (1G only) | |Engine prime 1g |{{:​engineprime-1g.properties|engineprime-1g.properties}} ​ |1G DSM version of the above. (1G only) |
 +
 +
 +===== Direct code modifications =====
 +
 +
 +__**NOTE/​WARNING/​DISCLAIMER:​**__The files in this section are basically pushing raw code into the ECMLink firmware. If you type a single number wrong, you could easily cause the ECU to reset. And that's the best case scenario because ECMLink has a built-in failsafe for that type of error. The worst case scenario is that you somehow manage to type in a wrong number that doesn'​t reset the ECU but does introduce some undesirable side effects that may not even be obvious until you're powering down the track at full boost!
 +
 +
 +{{  :​direct-access-code-mod.png?​nolink&​185x63}}Each cell value you enter must match the value in the header above that cell. An example is provided to the right. Each cell value is identical to the header above it.
 +
 +
 +EDIT CAREFULLY AND __DOUBLE CHECK__ THE VALUES YOU ENTER BEFORE HITTING THE SAVE-TO-ECU BUTTON!! You have been warned.
 +
 +
 +^Name ^File ^Description |
 +|No Knock Retard |{{:​noknock1g.properties|noknock1g.properties}} ​ |Disables the knock retard function but still allows the value to be logged. (1G only) |
 +|::: | {{:​noknock2g.properties|noknock2g.properties}} ​ |2G version of above |
 +|::: | {{:​noknocke3.properties|noknocke3.properties}} ​ |EVO1-3 version of above |
  
  
 \\ \\
  
direct_access_changes.txt ยท Last modified: 2024/03/15 11:16 (external edit)