User Tools

Site Tools


v3changelog

This is an old revision of the document!


ECMLink (V3) Laptop Application Changelog

3.19.6 (8/7/2009)

  • Increased contrast on selection highlighting with direct access tables

3.19.3 (8/3/2009)

  • Added logic to speed up large table updates (like the speed density table)
  • Corrected spelling of Celsius 8-O
  • Added more EVO1-3 support functions, including speed density
  • Added experimental “save to ECU as changes are made” button. USE WITH CARE! This can act flaky if you are making changes while datalogging at the same time. We'll either fix that behavior or remove this function, depending on the level of interest and testing results.

3.18.239 (7/15/2009)

  • Updated linear wideband property names to indicate lambda instead of boost
  • Enabled “raw” and “hex” views to direct access tables
  • First release of EVO1-3 support added to application

3.18.230 (7/6/2009)

  • Added support for the Omni Power 3 and 4-bar sensors. These can be datalogged, used for speed density operation or used for MAFClamp functions.

3.18.205 (6/13/2009)

  • Added initial speed density documentation
  • Corrected glitch in AEMWB Gauge R1 mapping at 0.62v and 4.52v

3.18.196 (6/5/2009)

  • Fixed bug in detached-tables when minimizing and then restoring the application's main window
  • Corrected inversion bug in SD table update wizard
  • Added “tip in” correction table to direct access

3.18.182 (5/24/2009)

  • Adjusted GM 3-bar display routine to precisely match Delphi specification. This was actually a VERY minor change.
  • Made some design changes to support new device “plug in” modules coming later.
  • Made reboot/reconnect after direct access update much faster.
  • Added framework to application to support new SD features coming soon.
  • Fixed minor bugs in direct access display (like making color maps optional)

3.18.116 (3/20/2009)

  • Added function to allow live cell highlighting of various direct access tables
  • Added function to detach various direct access tables from the application as floating windows.
  • Added ability to individually color graph legend items.
  • Slight change to BoostEst definition that may cause this item to disappear from your graph legend. Simply add it back using the Display Values dialog box if this happens.
  • Small adjustment to LC1WB display routine to improve accuracy
  • Added application version string to About box
  • Added a few help file pages for functions that will be available in future firmware upgrades. You can ignore these until the firmware upgrade is available. These pages include Speed Density, AuxMaps, and EGR.

3.18.44 (1/12/2009)

  • Improved the MAF adjustment helper - MAFComp Adjust (CombinedFT)
  • Added support for estimated HP and Torque for V1/V2 ECUs
  • Fixed bug in datalog export function where the running timestamp was being reported as RPM

3.18.33 (1/1/2009)

3.17.158 (12/30/2008)

  • Fixed bug with reset LTFT function when used with a DSMLink (V2) ECU
  • Added V3 MAF Compensation global scalar “helper” to help auto center the MAF compensation table - MAF Adj: CombinedFT
  • Tweaked fuel calculator to provide an initial estimate of injector size and to allow for use of calculated global fuel adjustment
  • Added View menu items to edit ECU Config and DirectAccess data embedded in a datalog more easily

3.17.154 (12/26/2008)

  • Changed version number in about box (may require re-acceptance of license agreement)
  • Added some details to help file
  • Added reset of long term fuel trim ECU menu item
  • Added MAF adjustment “wizard” based on CombinedFT
  • Misc: added ClosedLoop, fixed 1G EGR log item, added 0.5 min-clip to AEM 3.5 and AEM 5-bar, added details to some direct access tabs

3.17.142 (12/15/2008)

  • Initial release